Skip to content
Offices, IT Rooms, Labs

Your Lab Suite on an ESD Floor Before Dublin Move-In Day

Dublin keeps adding office buildings near the 580 and 680 interchange, and some of the tenants moving in bring gear that a static spark can ruin: network closets, small device labs, test benches, a room of servers behind a glass wall. Johnny Mendoza lays ESD floors as part of a tenant build-out, works through your landlord’s approval, and checks the finished floor with a resistance meter.

JP Resin Certified · Don Resin Certified · Based in Hollister, Working Dublin

Johnny heads up 101 and 680 from Hollister to the office parks around Dublin’s freeway interchange.

Static control inside somebody else’s building

In Dublin, an ESD floor usually goes into space the tenant does not own. That changes the job before a grinder ever shows up. The landlord typically has to approve anything bonded to the slab, the property manager wants to know about dust and noise in a building where other tenants are working, and somebody has to decide what happens to the floor when the lease runs out.

Johnny starts with those lease questions because they shape the plan. He puts the build in writing for the landlord: the grinding, the copper grounding strips, where they tie into the building ground, the conductive primer and the body coat. Plain language helps a property manager say yes faster than a spec sheet nobody reads. It also helps to name who owns the system after install day, because the landlord will ask.

Get the landlord’s signature on the floor plan before the grinders arrive.

End of lease is the other half. Some landlords are happy to keep a good static control floor for the next tech tenant. Others want the space returned to bare slab, which means grinding the system back off. Knowing which one you signed up for changes how you budget the room.

Then the technical part. Conductive floors sit roughly between 25 thousand and 1 million ohms, dissipative roughly between 1 million and 1 billion. Whoever owns your static program, a parent company’s quality team or a customer contract, usually names the range, and Johnny builds to it.

Tenants Who calls about it here

Four Dublin suites that ask for a grounded floor

Each kind of tenant brings a different reason to control static and a different tolerance for downtime.

Network and IT rooms

Patch panels, switches and a rack or two behind a locked door. A tech who walks in from carpeted offices carries charge with every step. A static dissipative floor in that room, tied to the same ground as the racks, drains it before a hand touches open hardware.

Small device labs

A handful of engineers building prototypes on benches, with parts coming and going all week. The floor gets planned around the bench layout, with grounding points along the walls so the room can be rearranged later without cutting into the finished system.

Test and repair benches

Companies that service equipment, from radios to medical devices, often run a back room where boards get opened and soldered. That room can take the ESD system while the front office keeps ordinary flooring, with a clean transition line at the door.

Medical equipment rooms

Some imaging and equipment rooms in newer medical suites carry static requirements from the equipment maker. Johnny reads that installation guide first and builds to the maker’s own number, or tells you plainly when the room needs nothing special.

What a new building changes about the build

Newer office buildings make some of the work easier. The slab is usually flat, nobody has spilled forty years of oil on it, and the electrical room is close enough that confirming a solid building ground point is quick work for your electrician. The grind is mostly about opening the surface and pulling off the curing compound or sealer the original crew left.

Newer slabs bring their own catch. A building finished recently can still be pushing moisture up through the slab, and an ESD body coat laid over a wet slab can blister and lose contact with the copper beneath it. Johnny sets humidity probes before he chooses a primer, even when the building looks brand new. If the reading is high, a moisture-tolerant primer goes on the written price before anything starts.

Carpet tile is the usual starting point in a second-generation suite. The tile comes up, the adhesive gets ground off, and the copper strips go down in a pattern that reaches every area people stand. A conductive primer spreads charge into that copper, and the ESD epoxy or urethane on top carries the conductive fibers that make the surface work. Each layer has to be there, because the meter will find any gap. Where a room sits on a raised access floor for cabling, the static plan moves up to those panels and the slab below stays out of it.

A new slab looks dry long before it is dry.

Move-in deadlines and the readings you hand over

Tenant build-outs run on a date. The lease starts, the movers are booked, and the IT team wants the racks powered by a certain Monday. The ESD floor has to fit between the electrician, the drywall touch-up and the furniture install, so Johnny asks for the general contractor’s schedule early, slots the grinding before finish trades move in, and puts the coating near the end so ladders and carts do not scuff it.

In a building with other tenants, dust and noise get managed on purpose. Grinders run with vacuum dust collection, doors to the corridor get sealed, and the loud work lands in the hours your property manager approves. Johnny also tells the building which days the coats go down, so the neighbors are not caught off guard. Nobody next door should learn about your floor from a cloud of dust in the hallway.

Once it cures, the room gets read with a resistance meter at the benches, the racks, the doorway and the open floor, against the number your spec calls for. Those readings go to whoever runs your static program or into your landlord file. Plan a recheck after the first few months of cleaning. For the full comparison of conductive and dissipative systems, see the ESD flooring page.

What Dublin tenants and property managers ask Johnny

Will our landlord let us bond an ESD floor to the slab?

Many do, once they see the plan. Johnny writes up the full build in plain terms, including where the copper ties into the building ground and how the floor could come out later. Property managers mostly want to know about dust, hours and the end of the lease, and he answers all three up front.

The suite has carpet tile now. Can the ESD system go over the old glue?

The glue has to go. Carpet tile adhesive stays soft and would sit between the slab and the conductive layers, which means a weak bond and unreliable readings. It comes off in the grind along with any curing compound, and Johnny checks the bare slab for cracks and moisture before priming.

Does the whole suite need an ESD floor, or only the lab?

Usually only the rooms where people handle sensitive gear. Offices, conference rooms and the break area can keep carpet or a standard coating. The ESD system stops at a clean line, often a doorway, and every grounded area keeps its own connection to ground. Covering the whole suite mostly adds cost without adding protection.

Can you work at night so the other tenants are not bothered?

Often, if the building allows it. The grinding is the loud, dusty part, so that is what usually moves to evenings or a weekend, with vacuum dust collection running the whole time. The coats follow on a quieter schedule. Your property manager sets the hours, and Johnny plans the sequence around them.

Our janitorial service comes with the building. What do they need to know?

Mainly what to leave out. Wax and floor finish lay an insulating film on the surface, and some all-purpose cleaners leave residue that does the same. A neutral cleaner approved for static control floors is the safe pick. Johnny leaves product notes to pass along to the cleaning company, and a meter check later confirms nothing drifted.

How long before we can roll the racks back in?

Plan on a few working days for grinding, the copper, the primer and the body coat in a typical room, then cure time before foot traffic and a little longer before heavy racks roll over it. Johnny gives the real schedule at the site assessment so the IT team can book its move with room to spare.

Bring Johnny into the build-out early

Send Johnny the suite size, the move-in date, the spec your equipment or parent company works to and who manages the building. He drives up from Hollister, walks the space with your contractor or property manager, probes the slab and writes a price that breaks out prep, grounding and finish.

Finished floors live in the gallery. Have a landlord packet or a spec sheet? Send it over here and Johnny will read it before the walkthrough.